Silju-John Kunnkattu, Theresia Gross, Sandra Stoppelkamp, Juvano Knieps, Torsten Remmler, Stefan Fennrich, Hans Peter Wendel, Nicole Rauch
Potential of a piezo-based measuring method (PAV) as a haemostasis monitoring system compared to a rotational rheometer

Appl. Rheol. 27:1 (2017) 13540 (11 pages)

In modern intensive care a comprehensive solution for monitoring the coagulation status or blood clotting problems is currently not available, because fast reliable detection of all bleeding-based disorders (coagulation, fibrinolysis, platelet function) cannot be conducted with a single medical device. This situation calls for a comprehensive technical solution, which we think possible to be solved with a rheological piezo-based system. Rheological measurements provide valuable information on the viscoelastic properties of complex fluids. Here, we compared the performance of a commercially available rheological industrial device using shear stress (Kinexus Pro, Malvern) with that of a piezo-based research measuring system (piezoelectric axial vibrator, PAV) applying squeeze flow to sample fluids. Comparative measurements using different xanthan concentrations (0.1 to 5%) were carried out at 25 and 37 °C. At higher concentrations (1, 2, and 5%), there was an overlapping frequency range and a consistent range of the viscous and elastic shear viscosity for both systems, allowing direct comparisons. Specifically the lower concentrations of 0.1, 0.2, and 0.5% xanthan could be used to assess the possibility of both systems to measure blood coagulation, as those concentrations correspond approximately to the viscosity of human blood. Measurement of blood coagulation was then also tested with the PAV. Measurement repeatability was assessed performing blood coagulation measurements over time at different frequencies (10, 100, 300, and 1000 Hz). The middle frequencies of 100 and 300 Hz provided the most repeatable results for blood. Afterwards the activated clotting time (ACT) was performed with PAV at 300 Hz. The piezo-based measuring system was able to differentiate between various heparin blood concentrations (1, 2, and 3 IU/ml). In this study the reliability, repeatability and limitations of the piezo system were examined. Our initial results showed that the piezo system can be used to assess blood coagulation, but further studies are necessary to confirm these promising results. The aim of a fast, small and reliable point-of-care system may be possible with this type of rheological device.

Cite this publication as follows:
Kunnkattu S, Gross T, Stoppelkamp S, Knieps J, Remmler T, Fennrich S, Wendel HP, Rauch N: Potential of a piezo-based measuring method (PAV) as a haemostasis monitoring system compared to a rotational rheometer , Appl. Rheol. 27 (2017) 13540.


© Applied Rheology 2024